The product

The innovative and unique disposable PFT (Peristaltic Feeding Tube), that is monitored and controlled 24/7 by the bedside CMU, brings a novel solution to the problem of gastric reflux towards the oropharynx when enteral feeding is employed. The LunGuard PFT mimics the physiology of the natural peristaltic mechanism of the esophagus. The PFT is designed to prevent reflux induced aspiration while at the same time allow liquids (such as saliva) to flow down the esophagus.

The system is comprised of two parts:

CMU - The CMU controls the PFT’s balloons activity, inflating and deflating them, keeping the correct (ongoing balance between efficacy & safety) amount of pressure at all times.

PFT - The disposable portion of the system functions as an NG tube having three inflatable balloons in a row situated close to the sphincter. After insertion, the three balloons inflate (one, at a time), thereby sealing off the esophagus preventing reflux from rising. The peristaltic tube, in addition to its blockage capabilities, is used as continuous esophagus motion sensor, with self adjustment algorithm that makes the optimal 24/7 balance between max efficacy and optimal safety pressures on internal esophagus tissues.

When liquids coming down the esophagus (such as saliva), the PFT’s peristaltic mechanism “pushes” the liquid down into the stomach while at the same time prohibiting stomach content from rising up.

Click here to enlarge picture

The smart next PFT generation that will be furbished with a forth distal balloon, will used us a massive reflux episodes sensor and will be able utilize as an unexpected vomiting content blockage so eliminate the movement of such content towards the respiratory system.

 

The vision - "Closing the nutritional loop…"

Early feeding is one of the significant accelerators related to patient recovery yet there are associated side effects due to intensive nutrition administration directly to the stomach. LunGuard bring a new approach with "Feed as need" concept meaning the care giver has the option to calibrate feeding rate as needed without concern for stomach content movement towards the respiratory system and its potential complications. LunGuard CMU (Control & Monitoring Unit) will capture, continuously, essential parameters of the stomach and gastric content existence in the esophagus, process the data and communicate with the feeding pump for optimal and safe continuous nutrition.

Learn more

Overview

LunGuard is dedicated to the development of advanced enteral feeding equipment. The Company is developing a unique and proprietary device for the enteral feeding market. ...

Read more

 

The need

Enteral feeding refers to the delivery of liquid feedings through a tube. Enteral feeding, are used in patients who have a functioning gastrointestinal tracts, but are un...